Pneumatic protection of water towers
Pneumatic protection of water towers

Pneumatic protection of water towers

DOI: 10.37153/2618-9283-2023-1-54-67

Authors:  

Сабирова Ойпошша Бахтияровна Oyposhsha B. Sabirova
engineer, Emperor Alexander I St. Petersburg state transport university, "Industrial and civil construction" department. Russian Federation, St. Petersburg

Зенченкова Диана Вениаминовна Zenchenkova Diana V.
Candidate of Technical Sciences, Associate Professor of the Department of Buildings, PGUPS. Saint Petersburg, Russian Federation


Rubric:     Seismic safety and seismic isolation of buildings   
Key words: pneumatic protection, earthquake-resistant water towers, computational and dynamic model, volume of pneumatic protection, vibration patterns
Annotation:

The paper discusses the effectiveness of using pneumatic protection to reduce seismic loads on a water tower. The tower carries a reservoir with a capacity of 30 m3. Air tanks, used as pneumatic protection, are placed along the reservoir perimeter in the zone of maximum hydrodynamic pressure. The volume of air was accepted according to the recommendations of O.A. Savinov and M.M. Peychev and is equal to 4 m3. The analysis of the hydrodynamic equations makes it possible to divide the liquid in the reservoir into two parts. One part is rigidly connected to the reservoir (attached mass of liquid), and the second part is connected with the tank by a spring simulating an air shock absorber. In the performed calculations, the added mass was 14 tons. The effect of the seismic load decrease was less than expected. This is due to the fact that the structure of the tower itself is quite heavy, and the load from its own weight is approximately equal to the load caused by the weight of the liquid. Therefore, doubling the liquid load reduces the total load by only 25%.

Purpose: To increase the seismic resistance of water towers by applying pneumatic protection. Traditionally, the seismic resistance of water towers is provided by a constructive solution of the tower shaft; in this case, increasing the seismic resistance of already operated towers is problematic. In this regard, the task was set to change the dynamic characteristics of the structure through the use of pneumatic protection directly in the reservoir of the structure.

Methods: The article discusses the constructive solution of internal pneumatic protection and the method of calculating water towers with its application to seismic loads, and evaluates the effectiveness of this type of seismic protection. A numerical calculation of the volumes of pneumatic protection and numerical values of the parameters of the calculation-dynamic model of the design of a water tower with internal pneumatic protection in relation to the A.A. Rozhnovsky. Calculations for seismic impact have been performed and forces in the structural elements of a water tower without pneumatic protection and with its installation have been determined.

Results: A comparative analysis of the oscillations of a water tower without pneumatic protection and with it was carried out. The results show that in the presence of pneumatic protection, the dynamic characteristics of the system change, which leads to a decrease in seismic loads and a significant decrease in the forces in the design of the water tower, including in the shaft.

Practical significance: The device of internal pneumatic protection will ensure seismic resistance, including operated water towers in those areas where the seismicity of the construction site has been increased due to the revision of general seismic zoning maps. Internal pneumoprotection makes it possible not to provide for additional insulation of pneumoprotective installations, since they are located inside the tank. In addition, this solution facilitates the operation of a water tower equipped with pneumatic protection, since the structural elements of the device are protected from external influences.

Used Books:

1. Kotov V.I. Industrial solutions of trunks of water towers. Industrial construction of engineering structures. 1989, no. 4, pp. 34–35 [In Russian]

2. Spivak E.S. On the issue of the dynamic effect of seismic waves on a tower structure. Calculation of building structures. Kiev, 1970, pp. 23–30 [In Russian]

3. Nikolaenko N.A. Dynamics and seismic resistance of structures bearing tanks. M.: Gostroizdat, 1962, 90, p. 88 [In Russian]

4. Eisenberg J.M. Structures with switching connections for seismic areas M.: Stroyizdat, 1976. 229 p. [In Russian]

5. Polyukh V.S. Water towers. Designing. / V.S. Polyukh, M.: Stroyizdat, 1980, 351 p. [In Russian]

6. Niskin E.A. Calculation of steel vertical tanks for seismic impacts. M.: VPI Teploeelectroproekt, 1998, 189 p. [In Russian]

7. Savinov O.A., Uzdin A.M. Assignment of the level of calculated impact in the assessment of seismic resistance of large hydraulic structures. Express-information VNIIIS. Series 14. Earthquake–resistant construction, 1980, Issue 2, pp. 21–25 [In Russian]

8. Savinov O.A., Sheinina S.I. On the analysis of the seismic properties of the air curtain. Izvestiya VNIIG, 1980, 1. 140, pp. 84–89 [In Russian]

9. Sheinina S.I. The effectiveness of an air curtain under the influence of time–varying pressure on the surface of a reservoir. Izv. VNIIIG named after B.E. Vedeneev. 1984, vol.170, pp. 46–53 [In Russian]   

10. Peychev M.M. Prospects for the construction of water towers in seismic areas. Design and calculation of building structures. L., 1986, pp.45–51 [In Russian]

11. Uzdin A.M., Peychev M.M., Peycheva Yu.S. Calculation of water towers for seismic impacts. Construction in special conditions. Express information of VNIIIS. Series 14, 1986, Issue 2, pp. 21–27 [In Russian]

12. Uzdin A.M., Elizarov S.V., Belash T.A. Earthquake–resistant structures of transport buildings and structures: textbook. M.: FSBEI "Educational and Methodological Center for Education in Railway transport". 2012. 501 p.

13. Patent No. 13599428 USSR.: Water tower: application 04.04.1986 publ. 15.12.1987: bul. No. 46: Savinov O.A., Uzdin A.M., Peychev M.M., 2 l.: ill.